Head module for the modular safety relay myPNOZ,
communication with expansion modules, supply voltage for myPNOZ,
1 input function, 2 test pulse outputs for detection of shorts acrosscontacts
and short circuits, 1 signal output, 1 rotary switch for selecting the
functions, 1 rotary switch for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
2 input functions, input functions AND-linked,
2 signal outputs, 2 rotary switches for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
2 input functions, input functions OR-linked,
2 signal outputs, 2 rotary switches for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 input function, 1 input function for connection to a
two-hand pushbutton (Type III A), input functions AND-linked,
1 signal output, 1 rotary switch for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 input function, 1 input function for connection to a
two-hand pushbutton (Type III C), input functions AND-linked,
1 signal output, 1 rotary switch for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
connection for supply voltage to the semiconductor outputs,
1 input function, 2 output functions, each with 1 safe
semiconductor output, instantaneous, and 1 input for feedback loop,
2 signal outputs, 1 rotary switch for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 input function, 1 output function with 3 safe relay outputs,
positive guided, instantaneous, and 1 input for feedback loop,
2 signal outputs, 1 rotary switch for setting the start type and
test pulse evaluation, LED display
On request
Expansion module for the modular safety relay myPNOZ,
connection for supply voltage to the semiconductor outputs,
1 input function, 1 output function with 1 safe semiconductor output,
instantaneous, and 1 input for feedback loop, 1 output function with 1
safe semiconductor output, delayed, and 1 input for feedback loop,
2 signal outputs, 1 rotary switch for setting the start type and
test pulse evaluation, 1 rotary switch for setting the delay time,
1 rotary switch for the factor setting for the delay and for selecting
the off or on-delay, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 input function, 1 output function with 3 safe relay outputs,
positive guided, delayed, and 1 input for feedback loop,
2 signal outputs, 1 rotary switch for setting the start type and
test pulse evaluation, 1 rotary switch for setting the delay time,
1 rotary switch for the factor setting for the delay and for selecting
the off or on-delay, LED display
On request
Expansion module for the modular safety relay myPNOZ,
connection for supply voltage to the semiconductor outputs,
2 output functions, each with 1 safe semiconductor output,instantaneous,
and 1 input for feedback loop, 1 signal output, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 output function with 3 safe relay outputs, positive-guided,
instantaneous, and 1 input for feedback loop, 1 signal output,
LED display
On request
Expansion module for the modular safety relay myPNOZ,
connection for supply voltage to the semiconductor outputs,
1 output function with 1 safe semiconductor output, instantaneous, and 1
input for feedback loop, 1 output function with 1 safe
semiconductor output, delayed, and 1 input for feedback loop,
1 signal output, 1 rotary switch for setting the delay time,
1 rotary switch for the factor setting for the delay and for selecting
the off or on delay, LED display
On request
Expansion module for the modular safety relay myPNOZ,
1 output function with 3 safe relay outputs, positive guided,
delayed and 1 input for feedback loop, 1 signal output,
1 rotary switch for setting the delay time, 1 rotary switch for
the factor setting for the delay and for selecting the off or
on delay, LED display
On request
PNOZsigma safety relay (standalone), inputs: 1-channel wiring
wiring, manual/automatic start, outputs: 2 N/O, 1 SC, UB 24 V
DC, width: 12.5 mm, plug-in screw terminals, monitoring of
E-STOP, safety gates.
On request
PNOZsigma safety relay (standalone), inputs: 1-channel wiring
wiring, manual/automatic start, outputs: 2 N/O, 1 SC, UB 24 V
DC, width: 12.5 mm, plug-in spring-loaded terminals, monitoring ofE-STOP
, safety gates.
On request
PNOZsigma safety relay (standalone), inputs: 1-channel wiring
wiring without detection of shorts across contacts, manual/automaticstart,
outputs: 3 N/O, 1 N/C, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates.
On request
PNOZsigma safety relay (standalone), inputs: 1-channel
wiring without detection of shorts across contacts, manual/automaticstart,
outputs: 3 N/O, 1 N/C, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates.
On request
PNOZsigma safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, manual/automatic
start, outputs: 2 N/O, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in
plug-in terminals of screw type, monitoring of E-STOP, safety gates,
light guard.
On request
PNOZsigma safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, manual/automatic
start, outputs: 2 N/O, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates, lightguard.
On request
PNOZsigma safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, manual/automatic
start, outputs: 3 N/O, 1 N/C, 1 SC, UB 24 V DC, width: 22.5 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light guard.
On request