Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 N/O t-d,
automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light curtain,
release time 12 levels 0.1 - 30 s.
On request
Safety relay (standalone), inputs: Per pushbutton 1 N/O, 1 N/C,
outputs: 3 N/O, 1 N/C, 2 SC, UB = 230 V AC, width: 45 mm, plug-in
screw terminals, two-hand control relay/monitoring of simultaneity
of two-hand pushbuttons, feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,
automatic/monitored start, UB 24 V AC/DC, width: 45 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O
automatic/manual/monitored start, UB 24 V AC/DC, width: 22.5
mm, plug-in screw terminals, monitoring of E-STOP, safety gates.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 3 N/O, 1 N/C, UB = 230 V AC, width: 90 mm,screw terminals
integrated, monitoring of E-STOP, safety gates, feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with detection of shorts across contacts, outputs: 7 N/O, 1 N/C, 1 SC,
automatic/manual/monitored start, UB 24 V AC/DC, width: 90 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O
automatic/manual/monitored start, UB 24 V AC/DC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O, UB
24 V DC, width: 25 mm, screw terminals integrated, contact block for
contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 5 N/O, 1 N/C,UB 24 V DC, width:
45 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O, UB
24 V DC, width: 25 mm, plug-in screw terminals, contact block for
contact expansion in connection with safety-related
control components.
On request
Safety relay (standalone), inputs: 2-channel wiring
with detection of shorts across contacts, outputs: 6 N/O, 4 N/C, UB = 24V DC, width: 90
mm, screw terminals integrated, safety gate monitor,
simultaneity monitoring approx. 4 s, feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, 2N/O t-d, UB = -24 V DC
(Japan), width: 112.5 mm, screw terminals integrated, monitoring of
E-STOP, safety gates, feedback loop, with two independently adjustable
delay-on de-energisation contacts, release time 12 levels from 1 - 20 sand 0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,UB = 48 V AC, width:
90 mm, screw terminals integrated, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 STD,
automatic/manual start, UB 24 V DC, width: 112.5 mm,
screw terminals integrated, monitoring of E-STOP, safety gates, with
two independently adjustable delay-on de-energisation contacts,
release time 12 levels from 1 - 20 s/0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,UB = 24 V DC, width:
90 mm, screw terminals integrated, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,UB = 230 - 240 V AC/DC,
width: 90 mm, screw terminals integrated, monitoring of E-STOP,
safety gates, feedback loop.
On request
PZW 30/24VDC 1n/o 2n/c
Phase-out article
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, pulsing timer relay, monitoring feedback loop,
pulse times 12 levels from 0.5 - 30 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 1 N/C, automatic/manual start, UB = 24 V AC/DC,
width: 22.5 mm,screw terminals integrated, monitoring of E-STOP,
safety gates, feedback loop.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 2 N/O, automatic/manual start, UB = 240 V AC, width:
22.5 mm, screw terminals integrated, monitoring of E-STOP,
safety gates.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 2 N/O, automatic/manual start, UB = 120 V AC, width:
22.5 mm, screw terminals integrated, monitoring of E-STOP,
safety gates.
On request