Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/O
t,
automatic/monitored start, UB 24 V DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, release time 12
levels 0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm,
plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.3 - 300 s),
automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 N/O t-d,
automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light curtain,
release time 12 levels 0.1 - 30 s.
On request
PZW 30/24VDC 1n/o 2n/c
Phase-out article
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, pulsing timer relay, monitoring feedback loop,
pulse times 12 levels from 0.5 - 30 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 230 V AC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 3 - 30 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 3 - 30 s.
On request
PZW 3/24VDC 1n/o 2n/c
Phase-out article
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, pulsing timer relay, monitoring feedback loop, pulse times
12 levels from 0.05 - 3 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 60 - 600 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 30 - 300 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 24 V DC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 0.3 - 3 s.
On request
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 1 N/O, 2 N/C, UB = 230 V AC, width: 45 mm, screw terminals
integrated, delay-on energisation timer relay, monitoring feedback loop,
energisation times 12 levels from 30 - 300 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with detection of shorts across contacts, outputs: 2 N/O, 2 N/O t-d, UB= 24 V DC, width: 90
mm, screw terminals integrated, E-STOP monitoring,safety gates
with 2 delay-on de-energisation contacts, release time 12 levels from0.3 - 300 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/Ot-d, UB = 24 V DC,
width: 45 mm, screw terminals integrated, E-STOP monitoring,
safety gates, with 2 delay-on de-energisation contacts, delay time
can be set in 12 levels from 0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/Ot-d, UB = 24 V DC,
width: 45 mm, screw terminals integrated, E-STOP monitoring,
safety gates, with 2 delay-on de-energisation contacts, delay time
can be set in 12 levels from 0.1 - 30 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with detection of shorts across contacts, outputs: 2 N/O, 2 N/O t-d, UB= 24 V DC, width: 45 mm,
screw terminals integrated, E-STOP monitoring, safety gates,
with 2 delay-on de-energisation contacts, release time 3 s fixed.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/Ot-d, UB = 24 V DC,
width: 45 mm, screw terminals integrated, E-STOP monitoring,
safety gates, with 2 delay-on de-energisation contacts, delay timepermanently
set 0.5 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 4 N/O t-d, 1SC instantaneous, UB = 24
V DC, width: 45 mm, screw terminals integrated, E-STOP
monitoring, safety gates with 4 delay-on de-energisation contacts,release time 1 s
fixed.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d, UB = 24 V DC,
width: 90 mm, screw terminals integrated, E-STOP monitoring,
safety gates, with 2 delay-on de-energisation contacts, delay time
can be set in 12 levels from 0.1 - 30 s.