Close
You are on the Pilz international website
Please select a language or switch to a country
Choose your country to get national content
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm,
plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d (t
= 2 s fixed), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.3 - 300 s),
automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d,(t=
1 s fixed), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d,(t
= 0.5 s fix), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.3 - 300 s),
automatic/monitored start, UB 24 - 240 V AC/DC, width: 90
mm, plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Contact expansion, inputs: 1/2-channel wiring without
detection of shorts across contacts, outputs: 4 N/O, UB 24 V DC,
width:22.5 mm
plug-in screw terminals, contact block for contact expansion in
connection with safety-related control components.
On request
Contact expansion, inputs: 1/2-channel wiring without
detection of shorts across contacts, outputs: 4 N/O, UB = 24 - 240 VAC/DC, width: 45
mm, plug-in terminals of screw type, contact block for
contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring,
outputs: 2 N/O, 1 N/C, 2 SC, UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 VAC/DC,
UMmax = 690 V, width: 45 mm, standstill monitor, coated version.
The device monitors the EMC voltage created during
motor rundown.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/C,2 SC
automatic/monitored start, UB 24 V DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light guard.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,
automatic/monitored start, UB 24 V DC, width: 90 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light guard
sidewards compatibility with PNOZ X10.1.
On request
Safety relay (standalone), inputs 2-channel wiring
with/without detection of shorts across contacts, 4 muting sensors,outputs: 3 N/O, 1 N/C, 5
SC, automatic/monitored start, UB = 24 V DC, width: 90 mm,
plug-in terminals of screw type, device for brief suspension of
safety functions, muting, monitoring of
muting lamps and their automatic switching.
On request
Safety relay (standalone), inputs: 1/2-channel wiring,
outputs: 2 N/O, 1 N/C, 2 SC, UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 VAC/DC,
UMmax = 690 V, width: 45 mm, standstill monitor. The device monitors
the EMC voltage created when motors run down.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC,
automatic/monitored start, UB = 12 V DC, width: 90 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d,
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates,
light curtain, release time 0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d,
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates,
light curtain, release time 1 - 30 s.
On request
Safety relay (standalone), inputs: 2-channel wiring
with detection of shorts across contacts, outputs: 2 N/O, 1 SC, manualstart, UB = 24
V DC, width: 22.5 mm, spring-loaded terminals not plug-in,
safety relay for evaluating sensors with 2 SC outputs,
compact height.
On request
PNOZsigma contact expansion, outputs: 2 SC safety outputs 1
standard SC output, UB = 24 V DC, width: 22.5 mm plug-in
screw terminals, expansion module for expansion in connection with
safety-related control components.
On request
PNOZcompact safety relay (standalone), inputs: 2-channel
wiring with detection of shorts across contacts, manual/automatic start,
outputs: 3 N/O, 1 N/C, UB 24 V DC, width: 22.5 mm, spring-loadedterminals fixed
at the front of the unit, monitoring of E-STOP, safety gates.
On request
PNOZsigma, 2x relay expansion module for connection to PNOZ s30,
PNOZ mm0.1p and PNOZ mm0.2p, 2 separate controls for each 3 N/O
+ 1 N/C, plug-in screw terminals.
On request
Added to Your Shopping Cart
Save basket
Create a new order or get an individual offer